The Instrumentation Calculator App is very useful in day to day activities of an instrumentation engineer.
The Instrumentation Calculator App Key contributions:
★ Instrumentation Maintenance Activities
★ Field Transmitters Troubleshooting
★ Useful During Loop Checks
★ Useful During Logic Checks
★ Useful During Commissioning of a Plant
★ DCS & Field Reading mismatch calculations
★ Instrument Main cable Faults
★ Cable Voltage/Current Drops due to Resistance
★ DCS/ESD/PLC Analog input / Analog output 4-20 mA Calculations etc...
The Instrumentation Calculator App Functions as follows :
★ Calculate 4-20 mA Current from Process Variable, LRV & URV
★ Calculate Process Variable from 4-20 mA, LRV & URV
★ Calculate 0-100 % Percentage from 4-20 mA Current
★ Calculate 4-20 mA Current from 0-100% Percentage
★ Calculate 0-100 % Percentage from Process Variable
★ Calculate Process Variable from 0-100 % Percentage
Note: Process Variable, LRV & URV units must be same.
Support Our Instrumentation Calculator App: Like it, Share it, Give Comments & Encourage us.
How to Use Instrumentation Calculator App:
1. Enter the Lower Range Value (LRV) of the Field Transmitter.
(Minimum Value of the Transmitter Range)
2. Enter the Upper Range Value (URV) of the Field Transmitter.
(Maximum Value of the Transmitter Range)
3. Select the Input type i.e. any one of the list - Process variable, 4-20 mA Current & Percentage.
(Say you want to calculate the mA current output from Process Variable then Select Input as Process variable.)
4. Enter the Input Value depending on the above selection.
(Say you selected the Process Variable in above selection list then enter the Process Variable (PV) Value.)
5. Select the required Output type in the drop down list.
(Say you are calculating the mA current from Process Variable, So output type is 4-20 mA.)
6. Press Calculate button & the result is shown below the button.
EXAMPLE:
A Temperature Transmitter having a range of 0 to 150 Deg C and showing a Value of 125 Deg C in the field. Calculate equivalent 4-20 mA Current output.
Simply from the question, we need to calculate 4-20 mA from the Process Variable
Requirement
Select Input type = Process Variable
Select Output type = 4-20 mA
Enter the following data in the app
LRV = 0 Deg C
URV = 150 Deg C
Process Variable (PV) = 125 Deg C
Note: LRV, URV, Process Variable units must be same & not required to enter in the app.
Press Calculate & Result shown below the calculate button
Result = 17.33 mA
That's it, Very Simple to use.
Support Our Instrumentation Calculator App: Like it, Share it, Give Comments & Encourage us.
Instrumentasi Kalkulator App ini sangat berguna dalam kegiatan sehari-hari dari seorang insinyur instrumentasi.
Instrumentasi Kalkulator App kontribusi Key:
★ Instrumentasi Pemeliharaan Kegiatan
★ Pemancar Bidang Masalah
★ Berguna Selama loop Cek
★ Berguna Selama Logic Cek
★ berguna Selama Commissioning Menanam
★ DCS & Field perhitungan Membaca mismatch
★ Instrumen utama kabel Kesalahan
★ Kabel Tegangan / Current Drops karena Resistance
★ DCS / ESD / input PLC analog / output Analog 4-20 mA Perhitungan dll ...
Instrumentasi Kalkulator App Fungsi sebagai berikut:
★ Hitung 4-20 mA sekarang dari Proses Variabel, LRV & URV
★ Proses Hitung Variabel 4-20 mA, LRV & URV
★ Hitung 0-100% Persentase 4-20 mA sekarang
★ Hitung 4-20 mA sekarang dari 0-100% Persentase
★ Hitung 0-100% Persentase dari Proses Variable
★ Proses Hitung Variabel dari 0-100% Persentase
Catatan: Proses Variabel, LRV & URV unit harus sama.
Mendukung Instrumentasi kami Kalkulator App: Suka, Share it, Berikan Komentar Mendorong kita.
Cara Menggunakan Instrumentasi Kalkulator App:
1. Masukkan Bawah Rentang Nilai (LRV) dari Transmitter Field.
(Nilai minimum dari Transmitter Range)
2. Masukkan Upper Rentang Nilai (URV) dari Transmitter Field.
(Nilai maksimum dari Transmitter Range)
3. Pilih jenis input yaitu salah satu dari daftar - variabel Proses, 4-20 mA Current & Persentase.
(Katakanlah Anda ingin menghitung arus keluaran mA dari Proses Variabel kemudian Pilih Masukan sebagai variabel Proses.)
4. Masukkan Nilai Masukan tergantung pada pilihan di atas.
(Katakanlah Anda memilih Variabel Proses dalam daftar pilihan di atas kemudian masukkan Proses Variable (PV) Nilai.)
5. Pilih jenis output yang diperlukan dalam daftar drop-down.
(Katakanlah Anda menghitung arus mA dari Proses Variabel, Jadi jenis output 4-20 mA.)
6. Tekan tombol Hitung & hasilnya ditampilkan di bawah tombol.
CONTOH:
Sebuah Transmitter Suhu memiliki berbagai 0-150 Deg C dan menunjukkan Nilai dari 125 Deg C di lapangan. Hitung setara 4-20 keluaran mA sekarang.
Cukup dari pertanyaan, kita perlu menghitung 4-20 mA dari Variabel Proses
Kebutuhan
Pilih jenis input = Proses Variabel
Pilih jenis output = 4-20 mA
Masukkan data berikut di app
LRV = 0 Deg C
URV = 150 Deg C
Proses Variable (PV) = 125 Deg C
Catatan: LRV, URV, Proses unit Variabel harus sama & tidak diperlukan untuk masuk dalam aplikasi.
Tekan Hitung & Hasil yang ditunjukkan di bawah tombol menghitung
Hasilnya = 17,33 mA
Itu saja, sangat sederhana untuk digunakan.
Mendukung Instrumentasi kami Kalkulator App: Suka, Share it, Berikan Komentar Mendorong kita.